🏭 20+ Years Factory Experience 🌍 Export to 50+ Countries

JNX-D3AK Mold Cooling Channel Electronic Pulse Cleaner

Electronic pulse technology with zero chemicals removes scale, oil and rust from inside cooling channels.

Voltage: 380V, 50HZ / 3.5KW Flow Display: 0–200 L/min measurement range Air Inlet Pressure: Min 0.4Mpa Cleaning Water Pressure: 0.2~0.5Mpa
JNX-D3AK Mold Cooling Channel Electronic Pulse Cleaner
20+
Years Factory Experience
32
32 Models
50+
50+ Countries
3 Years
3-Year Warranty

Core Technical Strengths

Guangdong Jieneng Electrical Appliance Technology Co., Ltd. (Shantou) — national high-tech & specialized enterprise

Instant vaporization · steam in 3 seconds
Boiler-less design
30 BAR pressure (vs. conventional 8 BAR)
BYD gear-cleaning case · patent ZL202111381080.6
Shaft patent CN120038147A
ATEX + EAC dual explosion-proof certification
Italian AR high-pressure pump
PLC automation
37 intellectual-property rights
3-year warranty

6 Core Advantages

Jieneng focuses on industrial cleaning equipment, every machine passes strict QC

Electronic Pulse Technology

High-frequency electronic pulses act directly on scale molecular structure, detaching it from pipe walls — no chemicals, no corrosion.

Zero Chemicals

Pure physical cleaning with no hydrochloric or citric acid — wastewater drains directly, meeting environmental standards.

In-Place Cleaning

No mold disassembly — connect to channel fittings and go. Cleaning plus drying in 4–8 hours.

Non-Damaging to Pipes

Pulses target only scale and rust, fully protecting mold channel walls and extending mold life.

Multi-Spec Adapters

Eight standard channel fittings cover 80%+ of injection-mold and hot-runner channels.

Touchscreen Control

7-inch industrial touchscreen shows pulse frequency, progress and pressure in real time.

Premium Craftsmanship, Visible Details

From core components to exterior details, excellence in every part

Industrial-Grade Chassis

Industrial-Grade Chassis

1.5 mm cold-rolled steel with powder coating — corrosion-resistant and durable.

Imported Pulse Generator

Imported Pulse Generator

German IGBT module delivers stable pulse frequency with a 10,000-hour service life.

Food-Grade Hoses

Food-Grade Hoses

Food-grade silicone hoses — non-toxic, odorless and FDA-compliant.

Intelligent Temperature Control

Intelligent Temperature Control

PID control holds cleaning fluid at 50–60°C for optimal cleaning efficiency.

Standard Accessories

Ready to use out of the box, no extra purchase needed

🔧
Delivered per the product page configuration list
× 1set

Technical Specifications

Authoritative parameters, real and reliable data

Item Specification
ModelJNX-D3AK
Product NameMold Cooling Channel Electronic Pulse Cleaner
OriginShantou, China
Voltage380V, 50HZ / 3.5KW
Flow Display0–200 L/min measurement range
Air Inlet PressureMin 0.4Mpa
Cleaning Water Pressure0.2~0.5Mpa
Cleaning Air Pressure0.6~0.9Mpa
Drying Function0.6–0.9 MPa (air pressure)
Outlet Pipe Design8-in/8-out φ10 quick couplings (1 set); 1-in/1-out 1" (1 set)
Main Pipe DiameterDN25
Total Tank Capacity100L
Corrosion-Resistant Variable-Frequency Pump3.0KW
Ambient Temperature5~65℃
Booster Pump0.6–0.9 MPa (air pressure)
Leak & Pressure TestMin 0.01Mpa
Cleaning ModeCavitation burst, pulse, one-way / reverse cleaning, mid-pause functions

Four-Layer Safety Protection

Dual safety for operators and equipment

1

Leakage Protection

Grounded machine cuts power in 0.1 s for absolute operator safety.

2

Pressure Monitoring

Real-time water-pressure monitoring with auto-stop above the safety threshold.

3

Over-Temperature Protection

Auto-cools when equipment exceeds 80°C.

4

Dual Grounding

Whole-machine dual grounding ensures safe operation.

Wide Application Scenarios

Covering 80%+ industrial cleaning scenarios

Injection Mold Channels

Injection Mold Channels

Removes scale, biofilm and rust from cooling channels to restore cooling efficiency and shorten cycle times.

Hot-Runner Systems

Hot-Runner Systems

Cleans fine channels of nozzles and manifolds, eliminating clogs that cause defects.

Die-Casting Molds

Die-Casting Molds

Cleans cooling channels to improve cooling uniformity and reduce part warpage.

Extruder Barrels

Extruder Barrels

Cleans barrel cooling channels to prevent clogging and lost output.

Rubber Vulcanizing Molds

Rubber Vulcanizing Molds

Cleans vulcanizing-mold channels to boost curing efficiency and reduce rejects.

Frequently Asked Questions

Answers to the most important questions from customers

What is electronic pulse cleaning?
High-frequency electrical pulses change the bond between water molecules and scale, so scale, rust and biofilm peel off pipe walls and flush out with the water — purely physical, non-damaging.
How does it compare to chemical cleaning?
Chemical cleaning uses hydrochloric/citric acid, corroding pipes and polluting the environment. Electronic pulse needs no chemicals — no corrosion, no pollution, and wastewater drains directly.
How long does cleaning one mold take?
A standard 50–100 m channel takes about 4–6 hours; shorter channels 2–3 hours; complex channels 8–12 hours.
Can it clean hot runners?
Yes. Our pulse frequency is optimized for fine hot-runner channels, cleaning micro-channels as small as 0.8 mm in diameter.
How often should molds be cleaned?
Every 6–12 months, depending on water quality and production frequency. Preventive cleaning before clogging is the lowest-cost, highest-return approach.

Get Product Quote Now

Our engineers will recommend the most suitable model and provide a customized quote based on your specific needs.